Expert Installation

Installation Methodology.

For the sake of safety and efficiency on your installations and overall Project management, LUXMANN insists that customers use one of several fully-licensed, fully qualified and specially trained Electrical Contractors who have been working closely with LUXMANN on many other installations of our LED products.

They are professional and many of them have been involved in our projects for over 4 years. They are extremely familiar with the inner workings of both the LUXMANN products as well as the applicable regulatory requirements by Electrical Regulatory Authorities Council (ERAC). Moreover, all these Electrical Contractors have the typical documentation needed for Government and Corporate work ie:

– WORKERS COMPENSATION INSURANCE
– PUBLIC LIABILITY INSURANCE
– SITE SAFETY STATEMENT
– SITE SAFETY and OH&S MANUAL/PLAN, incorporating
– SITE SAFETY POLICY
– ROLES AND RESPONSIBILITIES
– RISK MANAGEMENT
– INSPECTION, TESTING AND SERVICING
– HAZARD REPORTING
– HAZARDOUS SUBSTANCES
– FIRE PROTECTION
– GENERAL WORK PRACTICES
– INJURY MANAGEMENT
– SAFETY CHECK LIST
– OHS REFERENCES

Apart from offering a safe and efficient service, these teams will also examine your existing installation, report any deficiencies and make valid recommendations to improve your installation. In a typical flurescent tube the ingition energy is concentrated at the ends of the tube. The following common issue is a potential fire Hazard. We therefore suggest that you proceed with your LED tube replacement program before your tube fittings anthracise and the situation is irreversible requiring all new fittings.

 

In another common example, because of the inherent incompatibilities in some low-end electronic transformers, in many instances, our installation teams will suggest not to just replace the existing MR16 lamps. Instead, they will recommend using GU10 lamps and a GU10 lampholder kit, which are more efficient and will save you the additional 7.2Watts-11Watts consumed by the existing transformers and also help you eliminate a potential fire hazard.

In tube installations, there are no physical alterations required to your fittings. Our team of electricians will simply ‘bypass’ the Ballast and remove the Starter for each ‘non-emergency’ tube to be replaced with an LED tube. Due to the unique internal fusing of our tubes, there are no compliance issues resulting from this action. In addition, they will also quote for the replacement of the ‘Emergency’ tubes (including Battery and Inverter kits)

In addition to installation during business hours, they will also offer additional services such as:

– Working outside 9-5, Monday to Friday
– Repairing existing equipment and/or fittings
– Organising equipment hire
– Carrying out electrical monitoring and/or measurements at your premises
– Disposal and de-commissioning of existing lamps and/or fittings

Please refer to LUXMANN for typical installation costs.